Injection Molding Tolerance Guide (DIN 16742 / ISO 20457) for ABS, PA, POM & PPSU
Applying CNC metal tolerances (±0.02 mm) to a polypropylene or nylon drawing is the fastest way to double tooling cost without improving part performance. Here is how to specify realistic, CMM-verifiable tolerances using DIN 16742 / ISO 20457 standards.
1. Amorphous vs. Semi-Crystalline Resins: Why Material Dictates Tolerance
Shrinkage predictability—not just mold machining accuracy—sets the practical tolerance ceiling of any plastic part:
- Amorphous resins (ABS, PC, PC/ABS, PPSU): Low, uniform shrinkage (typically 0.4% – 0.8%). They hold tight tolerances cleanly across cosmetic enclosures and precision optical or high-temp baby bottle threads.
- Semi-crystalline resins (PP, PA6/PA66 Nylon, POM Acetal): Higher, directional shrinkage (1.2% – 2.5%) that varies between flow direction and transverse direction—and in Nylon, dimensions also shift slightly with post-molding moisture absorption.
2. Practical Production Tolerance Table (Tool-Bound Dimensions, TG5–TG7)
Under DIN 16742 / ISO 20457, dimensions formed inside a single solid mold half (tool-bound) hold tighter repeatability than dimensions crossing a parting line or moving slider (non-tool-bound).
| Nominal Size (mm) | ABS / PC / PPSU (Standard) | ABS / PC / PPSU (Precision) | PP / PA / POM (Standard) | PP / PA / POM (Precision) |
|---|---|---|---|---|
| ≤ 10 mm | ±0.10 mm | ±0.05 mm | ±0.15 mm | ±0.08 mm |
| 10 – 30 mm | ±0.14 mm | ±0.08 mm | ±0.20 mm | ±0.12 mm |
| 30 – 80 mm | ±0.20 mm | ±0.12 mm | ±0.30 mm | ±0.18 mm |
| 80 – 150 mm | ±0.30 mm | ±0.18 mm | ±0.45 mm | ±0.25 mm |
| Parting-Line / Slider Adder | Add +0.05 to +0.10 mm for features crossing a parting line, lifter, or hydraulic slide | |||
3. Five Engineering Controls That Let You Hold Tighter Tolerances
- Mark only 3–8 CTQ (Critical-to-Quality) dimensions on your 2D drawing: Let general geometry default to DIN 16742 TG6/TG7 while reserving tight ±0.05 mm calls strictly for bearing bores, PCB standoffs, waterproof O-ring grooves, and snap-fit catches.
- Use steel-safe initial cutting: For precision POM gears or press-fit motor bores, cut the cavity slightly steel-safe on T0 so dimensions can be EDM-tuned after measuring real resin shrinkage on CMM.
- Dry hygroscopic resins rigorously: Moisture in PA, PC, or PPSU causes viscosity swings that destabilize packing pressure and part weight. Our molding floor runs 94 dedicated resin dryers across 70+ presses for this exact reason.
- Balance multi-cavity runners and cooling: Cavity-to-cavity pressure imbalance produces parts that pass CMM on Cavity 1 but fail on Cavity 4.
- Inspect with CMM + 2D Optical FAI at T1: Never approve tooling purely by hand-caliper checks on soft or thin-walled parts—optical non-contact vision prevents clamping distortion during measurement.